Semi-skirted 96 PCR Plate

Antal artiklar 25
Sortera
FrameStar 96 semi skirted with upstand, purple frame, ABI® Style
4TI-0730

Overview

This ABI® Style PCR plate offers the benefits of our 2-component design to ABI® standard block users. This design combines the advantages of ultra-thin wall polypropylene tubes for optimum PCR results with a rigid polycarbonate skirt and deck for the highest thermal stability. Learn more about the features and benefits of the FrameStar range.

 

We recommend this semi-skirted plate for use with ABI® thermal cyclers and sequencers; it can be used directly with ABI® instruments with no adapters necessary. The only case where this is not true is with the ABI Fast Block thermal cyclers; in this case, using our FrameStar Fast Plate is recommended instead.

  • clear wells, purple frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate With Upstand, ABI® Style

Plate length: 124.26 ± 0.25mm

Plate width: 83.97 ± 0.25mm

Plate height: 23.20 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: <0.2ml (200µl)

Distance to center of A1 from top edge: 10.495 ± 0.25mm

Distance to center of A1 from left edge: 12.63 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 semi skirted with upstand, blue frame, ABI® Style
4TI-0730/B

Overview

This ABI® Style PCR plate offers the benefits of our 2-component design to ABI® standard block users. This design combines the advantages of ultra-thin wall polypropylene tubes for optimum PCR results with a rigid polycarbonate skirt and deck for the highest thermal stability. Learn more about the features and benefits of the FrameStar range.

 

We recommend this semi-skirted plate for use with ABI® thermal cyclers and sequencers; it can be used directly with ABI® instruments with no adapters necessary. The only case where this is not true is with the ABI Fast Block thermal cyclers; in this case, using our FrameStar Fast Plate is recommended instead.

  • clear wells, blue frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate With Upstand, ABI® Style

Plate length: 124.26 ± 0.25mm

Plate width: 83.97 ± 0.25mm

Plate height: 23.20 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: <0.2ml (200µl)

Distance to center of A1 from top edge: 10.495 ± 0.25mm

Distance to center of A1 from left edge: 12.63 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 semi skirted with upstand, clear frame, ABI® Style
4TI-0730/C

Overview

This ABI® Style PCR plate offers the benefits of our 2-component design to ABI® standard block users. This design combines the advantages of ultra-thin wall polypropylene tubes for optimum PCR results with a rigid polycarbonate skirt and deck for the highest thermal stability. Learn more about the features and benefits of the FrameStar range.

 

We recommend this semi-skirted plate for use with ABI® thermal cyclers and sequencers; it can be used directly with ABI® instruments with no adapters necessary. The only case where this is not true is with the ABI Fast Block thermal cyclers; in this case, using our FrameStar Fast Plate is recommended instead.

  • clear wells, clear frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate With Upstand, ABI® Style

Plate length: 124.26 ± 0.25mm

Plate width: 83.97 ± 0.25mm

Plate height: 23.20 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: <0.2ml (200µl)

Distance to center of A1 from top edge: 10.495 ± 0.25mm

Distance to center of A1 from left edge: 12.63 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 semi skirted with upstand, green frame, ABI® Style
4TI-0730/G

Overview

This ABI® Style PCR plate offers the benefits of our 2-component design to ABI® standard block users. This design combines the advantages of ultra-thin wall polypropylene tubes for optimum PCR results with a rigid polycarbonate skirt and deck for the highest thermal stability. Learn more about the features and benefits of the FrameStar range.

 

We recommend this semi-skirted plate for use with ABI® thermal cyclers and sequencers; it can be used directly with ABI® instruments with no adapters necessary. The only case where this is not true is with the ABI Fast Block thermal cyclers; in this case, using our FrameStar Fast Plate is recommended instead.

  • clear wells, green frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate With Upstand, ABI® Style

Plate length: 124.26 ± 0.25mm

Plate width: 83.97 ± 0.25mm

Plate height: 23.20 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: <0.2ml (200µl)

Distance to center of A1 from top edge: 10.495 ± 0.25mm

Distance to center of A1 from left edge: 12.63 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar® 96 semi skirted, purple frame, ABI® Style
4TI-0770

Overview

Specifically designed to be directly compatible with all major thermal cyclers, this plate can be used directly in ABI® 96 well instruments without the need for any adapters. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirt allows for labeling or barcoding for sample tracking. Learn more about the features and benefits of the FrameStar range.

  • clear wells, purple frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® Style

Plate length: 124.26 ± 0.25mm

Plate width: 83.97 ± 0.25mm

Plate height: 20.70 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: 0.2ml (200µl)

Distance to center of A1 from top edge: 10.495 ± 0.25mm

Distance to center of A1 from left edge: 12.63 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 semi skirted, blue frame, ABI® Style
4TI-0770/B

Overview

Specifically designed to be directly compatible with all major thermal cyclers, this plate can be used directly in ABI® 96 well instruments without the need for any adapters. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirt allows for labeling or barcoding for sample tracking. Learn more about the features and benefits of the FrameStar range.

  • clear wells, blue frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® Style

Plate length: 124.26 ± 0.25mm

Plate width: 83.97 ± 0.25mm

Plate height: 20.70 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: 0.2ml (200µl)

Distance to center of A1 from top edge: 10.495 ± 0.25mm

Distance to center of A1 from left edge: 12.63 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 semi shirted,(AB-1400), clear frame, ABI® Style
4TI-0770/C

Overview

Specifically designed to be directly compatible with all major thermal cyclers, this plate can be used directly in ABI® 96 well instruments without the need for any adapters. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirt allows for labeling or barcoding for sample tracking. Learn more about the features and benefits of the FrameStar range.

  • clear wells, clear frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® Style

Plate length: 124.26 ± 0.25mm

Plate width: 83.97 ± 0.25mm

Plate height: 20.70 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: 0.2ml (200µl)

Distance to center of A1 from top edge: 10.495 ± 0.25mm

Distance to center of A1 from left edge: 12.63 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 semi skirted, green frame, ABI® Style
4TI-0770/G

Overview

Specifically designed to be directly compatible with all major thermal cyclers, this plate can be used directly in ABI® 96 well instruments without the need for any adapters. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirt allows for labeling or barcoding for sample tracking. Learn more about the features and benefits of the FrameStar range.

  • clear wells, green frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® Style

Plate length: 124.26 ± 0.25mm

Plate width: 83.97 ± 0.25mm

Plate height: 20.70 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: 0.2ml (200µl)

Distance to center of A1 from top edge: 10.495 ± 0.25mm

Distance to center of A1 from left edge: 12.63 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 semi skirted, black frame, ABI® Style
4TI-0770/X

Overview

Specifically designed to be directly compatible with all major thermal cyclers, this plate can be used directly in ABI® 96 well instruments without the need for any adapters. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirt allows for labeling or barcoding for sample tracking. Learn more about the features and benefits of the FrameStar range.

  • clear wells, black frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® Style

Plate length: 124.26 ± 0.25mm

Plate width: 83.97 ± 0.25mm

Plate height: 20.70 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: 0.2ml (200µl)

Distance to center of A1 from top edge: 10.495 ± 0.25mm

Distance to center of A1 from left edge: 12.63 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 semi shirted, black frames, white wells, ABI® Style
4TI-0771

Overview

Specifically designed to be directly compatible with all major thermal cyclers, this plate can be used directly in ABI® 96 well instruments without the need for any adapters. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirt allows for labeling or barcoding for sample tracking. Learn more about the features and benefits of the FrameStar range.

  • white wells, black frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® Style

Plate length: 124.26 ± 0.25mm

Plate width: 83.97 ± 0.25mm

Plate height: 20.70 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: 0.2ml (200µl)

Distance to center of A1 from top edge: 10.495 ± 0.25mm

Distance to center of A1 from left edge: 12.63 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 semi skirted, frosted wells, clear frame, ABI® Style
4TI-0772

Overview

Specifically designed to be directly compatible with all major thermal cyclers, this plate can be used directly in ABI® 96 well instruments without the need for any adapters. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirt allows for labeling or barcoding for sample tracking. Learn more about the features and benefits of the FrameStar range.

  • frosted wells, clear frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® Style

Plate length: 124.26 ± 0.25mm

Plate width: 83.97 ± 0.25mm

Plate height: 20.70 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: 0.2ml (200µl)

Distance to center of A1 from top edge: 10.495 ± 0.25mm

Distance to center of A1 from left edge: 12.63 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 Well Semi-Skirted PCR Plate, standard profile
4TI-0900/C

Overview

The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirted allows for labeling or barcoding for sample tracking. Learn more about the features and benefits of the FrameStar range.

  • clear wells, clear frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate

Plate length: 127.76 ± 0.25mm

Plate width: 85.48 ± 0.25mm

Plate height: 20.70 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: <0.2ml (200µl)

Distance to center of A1 from top edge: 11.24 ± 0.25mm

Distance to center of A1 from left edge: 14.38 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 Well, white wells, Semi-Skirted PCR Plate
4TI-0901

Overview

The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirted allows for labeling or barcoding for sample tracking. Learn more about the features and benefits of the FrameStar range.

  • white wells, clear frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate

Plate length: 127.76 ± 0.25mm

Plate width: 85.48 ± 0.25mm

Plate height: 20.70 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: <0.2ml (200µl)

Distance to center of A1 from top edge: 11.24 ± 0.25mm

Distance to center of A1 from left edge: 14.38 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 Well Semi-Skirted PCR Plate, ABI® FastPlate Style
4TI-0910/C

Overview

This semi-skirted low profile plate is recommended for use with ABI® Fast block thermal cyclers. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well.

 

This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20µl.

 

The rigid polycarbonate skirt of this design eliminates warping and distortion during PCR, and makes it ideal for use with robotic systems. Its skirt also allows for labeling or barcoding.

  • clear wells, clear frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® FastPlate Style

Plate length: 127.70 ± 0.25mm

Plate width: 85.48 ± 0.25mm

Plate height: 16.70 ± 0.25mm

Well depth: 15.10 ± 0.10mm

Well diameter: 5.50 ± 0.10mm

Total well capacity: 0.2ml (200µl)

Working volume: <0.1ml (100µl)

Distance to center of A1 from top edge: 11.24 ± 0.25mm

Distance to center of A1 from left edge: 14.38 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 Well, white wells,Semi-Skirted PCR Pl.ABI®FastPlate Style
4TI-0911

Overview

This semi-skirted low profile plate is recommended for use with ABI® Fast block thermal cyclers. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well.

 

This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20µl.

 

The rigid polycarbonate skirt of this design eliminates warping and distortion during PCR, and makes it ideal for use with robotic systems. Its skirt also allows for labeling or barcoding.

  • white wells, clear frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® FastPlate Style

Plate length: 127.70 ± 0.25mm

Plate width: 85.48 ± 0.25mm

Plate height: 16.70 ± 0.25mm

Well depth: 15.10 ± 0.10mm

Well diameter: 5.50 ± 0.10mm

Total well capacity: 0.2ml (200µl)

Working volume: <0.1ml (100µl)

Distance to center of A1 from top edge: 11.24 ± 0.25mm

Distance to center of A1 from left edge: 14.38 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 Well, frosted w,Semi-Skirted PCR Pl, ABI® FastPlate Style
4TI-0912

Overview

This semi-skirted low profile plate is recommended for use with ABI® Fast block thermal cyclers. The low profile wells of this plate are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well.

 

This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20µl.

 

The rigid polycarbonate skirt of this design eliminates warping and distortion during PCR, and makes it ideal for use with robotic systems. Its skirt also allows for labeling or barcoding.

  • frosted wells, clear frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® FastPlate Style

Plate length: 127.70 ± 0.25mm

Plate width: 85.48 ± 0.25mm

Plate height: 16.70 ± 0.25mm

Well depth: 15.10 ± 0.10mm

Well diameter: 5.50 ± 0.10mm

Total well capacity: 0.2ml (200µl)

Working volume: <0.1ml (100µl)

Distance to center of A1 from top edge: 11.24 ± 0.25mm

Distance to center of A1 from left edge: 14.38 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 Well Semi-Skirted PCR Plate, Roche Style
4TI-0950/C

Overview

Our FrameStar Roche Style plates are designed to achieve optimized assay conditions on the Roche LightCycler® 96 and 480 (with 96 well block). This particular style of plate is in a low profile 96-well format; perfect for reaction volumes of 10-100µl.

 

The wells are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction.

 

This is especially recommended for reaction volumes below 20µl. The semi-skirted frame allows for labeling or barcoding.

  • clear wells, clear frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, Roche Style

Plate length: 127.70 ± 0.25mm

Plate width: 85.48 ± 0.25mm

Plate height: 15.60 ± 0.25mm

Well depth: 15.10 ± 0.10mm

Well diameter: 5.50 ± 0.10mm

Total well capacity: 0.2ml (200µl)

Working volume: <0.1ml (100µl)

Distance to center of A1 from top edge: 11.24 ± 0.25mm

Distance to center of A1 from left edge: 14.38 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 Well, white wells, Semi-Skirted PCR Plate, Roche Style
4TI-0951

Overview

Our FrameStar Roche Style plates are designed to achieve optimized assay conditions on the Roche LightCycler® 96 and 480 (with 96 well block). This particular style of plate is in a low profile 96-well format; perfect for reaction volumes of 10-100µl.

 

The wells are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction.

 

This is especially recommended for reaction volumes below 20µl. The semi-skirted frame allows for labeling or barcoding.

  • white wells, clear frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, Roche Style

Plate length: 127.70 ± 0.25mm

Plate width: 85.48 ± 0.25mm

Plate height: 15.60 ± 0.25mm

Well depth: 15.10 ± 0.10mm

Well diameter: 5.50 ± 0.10mm

Total well capacity: 0.2ml (200µl)

Working volume: <0.1ml (100µl)

Distance to center of A1 from top edge: 11.24 ± 0.25mm

Distance to center of A1 from left edge: 14.38 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar 96 Well Semi-Skirted PCR Plate, ABI Style, Low Binding
4TI-LB0770/C

Overview

Specifically designed to be directly compatible with all major thermal cyclers, this plate can be used directly in ABI® 96 well instruments without the need for any adapters. The rigid FrameStar 2-component design eliminates warping and distortion during PCR, making it ideal for use with robotic systems. The semi-skirt allows for labeling or barcoding for sample tracking. Learn more about the features and benefits of the FrameStar range.

  • 4ti-0770/C, with low DNA binding properties

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, ABI® Style

Plate length: 124.26 ± 0.25mm

Plate width: 83.97 ± 0.25mm

Plate height: 20.70 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: 0.2ml (200µl)

Distance to center of A1 from top edge: 10.495 ± 0.25mm

Distance to center of A1 from left edge: 12.63 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

FrameStar® 96 Well Semi-Skirted PCR Plate, Roche Style, High Sensitivi
4TI-0954

Overview

Our FrameStar Roche Style plates are designed to achieve optimized assay conditions on the Roche LightCycler® 96 and 480 (with 96 well block). This particular style of plate is in a low profile 96-well format; perfect for reaction volumes of 10-100µl.

 

The wells are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction.

 

This is especially recommended for reaction volumes below 20µl. The extra white wells allow for increased sensitivity in fluorescent assays. The semi-skirted frame allows for labeling or barcoding.

  • extra white wells, clear frame

 

Specifications

Parameter: FrameStar 96 Well Semi-Skirted PCR Plate, Roche Style, High Sensitivity

Plate length: 127.70 ± 0.25mm

Plate width: 85.48 ± 0.25mm

Plate height: 15.60 ± 0.25mm

Well depth: 15.10 ± 0.10mm

Well diameter: 5.50 ± 0.10mm

Total well capacity: 0.2ml (200µl)

Working volume: <0.1ml (100µl)

Distance to center of A1 from top edge: 11.24 ± 0.25mm

Distance to center of A1 from left edge: 14.38 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

96 well semi skirted PCR plate, natural
4TI-0760

Overview

All of our PCR plates are molded from virgin polypropylene under ISO certified cleanroom conditions in our UK-based production facility, and as such comply with the same stringent requirements as our FrameStar® range.

  •  clear

 

Specifications

Parameter: 96 Well Semi-Skirted PCR Plate

Plate length: 124.42 ± 0.25mm

Plate width: 84.02 ± 0.25mm

Plate height: 20.70 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: <0.2ml (200µl)

Distance to center of A1 from top edge: 10.51 ± 0.10mm

Distance to center of A1 from left edge: 12.71 ± 0.10mm

Pitch (distance between A1 and A2): 9.00mm

96 well semi skirted PCR plate, white
4TI-0761

Overview

All of our PCR plates are molded from virgin polypropylene under ISO certified cleanroom conditions in our UK-based production facility, and as such comply with the same stringent requirements as our FrameStar® range.

  • white

 

Specifications

Parameter: 96 Well Semi-Skirted PCR Plate

Plate length: 124.42 ± 0.25mm

Plate width: 84.02 ± 0.25mm

Plate height: 20.70 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: <0.2ml (200µl)

Distance to center of A1 from top edge: 10.51 ± 0.10mm

Distance to center of A1 from left edge: 12.71 ± 0.10mm

Pitch (distance between A1 and A2): 9.00mm

96well semi skirted plate for Roche LC480, low profile
4TI-0955

Overview

Low profile, 0.1 ml wells, polypropylene, cut corner H12, working volume: <100µl, total well capacity: 200µl; designed for use on Roche LightCycler 480. This Roche Style plate is designed to achieve optimized assay conditions on the Roche LightCycler 480. This particular style of plate is in a low profile 96-well format, perfect for reaction volumes of 10-100µl.

 

The wells are shorter than "standard" profile wells, which decrease the "dead space" between the heated lid of the thermal cycler and the sample in the well. This eliminates condensation forming on the side wall of the tubes, preventing reduction in PCR volume and increasing the efficiency of the reaction. This is especially recommended for reaction volumes below 20µl.

  • white

 

Specifications

Parameter: 96 Well Semi-Skirted PCR Plate, Roche Style

Plate length: 127.70 ± 0.25mm

Plate width: 85.48 ± 0.25mm

Plate height: 15.60 ± 0.10mm

Well depth: 15.10 ± 0.10mm

Well diameter: 5.50 ± 0.10mm

Total well capacity: 0.2ml (200µl)

Working volume: <0.1ml (100µl)

Distance to center of A1 from top edge: 11.24 ± 0.25mm

Distance to center of A1 from left edge: 14.38 ± 0.25mm

Pitch (distance between A1 and A2): 9.00mm

96 Well Semi-Skirted PCR Plate, ABI® Style, clear wells
4TI-0735

Overview

We recommend this semi-skirted plate for use with ABI thermal cyclers and sequencers. It can be used directly with ABI instruments with no adapters and no re-calibration of the instruments necessary. The only case where this is not true is with the ABI Fast Block thermal cyclers, in which case using our FrameStar® FastPlate is recommended instead.

 

All of our PCR plates are molded from virgin polypropylene under ISO certified cleanroom conditions in our UK-based production facility, and as such comply with the same stringent requirements as our FrameStar range.

  • clear

 

Specifications

Parameter: 96 Well Semi-Skirted PCR Plate With Upstand, ABI Style

Plate length: 126.00 ± 0.25mm

Plate width: 86.00 ± 0.25mm

Plate height: 22.10 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: <0.2ml (200µl)

Distance to center of A1 from top edge: 11.50 ± 0.10mm

Distance to center of A1 from left edge: 13.50 ± 0.10mm

Pitch (distance between A1 and A2): 9.00mm

96 Well Semi-Skirted PCR Plate, ABI® Style, Frosted wells
4TI-0736

Overview

We recommend this semi-skirted plate for use with ABI thermal cyclers and sequencers. It can be used directly with ABI instruments with no adapters and no re-calibration of the instruments necessary. The only case where this is not true is with the ABI Fast Block thermal cyclers, in which case using our FrameStar® FastPlate is recommended instead.

 

All of our PCR plates are molded from virgin polypropylene under ISO certified cleanroom conditions in our UK-based production facility, and as such comply with the same stringent requirements as our FrameStar range.

  • frosted

 

Specifications

Parameter: 96 Well Semi-Skirted PCR Plate With Upstand, ABI Style

Plate length: 126.00 ± 0.25mm

Plate width: 86.00 ± 0.25mm

Plate height: 22.10 ± 0.25mm

Well depth: 20.20 ± 0.10mm

Well diameter: 5.46 ± 0.10mm

Total well capacity: 0.3ml (300µl)

Working volume: <0.2ml (200µl)

Distance to center of A1 from top edge: 11.50 ± 0.10mm

Distance to center of A1 from left edge: 13.50 ± 0.10mm

Pitch (distance between A1 and A2): 9.00mm

 